Recovery and Replication of data
in Multitenant Applications:
This is a continuation of the
detailed article on recovery options. In next section, we discuss replication
options.
The example used here is a full
disaster recovery scenario for a multitenant SaaS application implemented with
the database per tenant model. The concepts introduced here are geo-restore and
geo-replication.
GeoReplication helps to create a
continuously synchronized readable secondary database for a primary database.
It is preferable although not required to have the secondary database in a
different region. Since this kind of secondary database is merely readable, it
is called a georeplica. This option serves to perform quick recovery of
individual databases in case of a regional disaster or a large-scale outage.
Once georeplication is setup, a geo-failover helps maintain continuity of
business.
There can be at most four
geo-secondaries for a single primary. Multiple geo-secondaries are tactical
redundancy. Additional secondaries can also be used to scale out read-only
workloads. If there’s only one secondary and it fails, the application is
exposed to higher risk until a new secondary is created.
Each geo-secondary can be a single
database or a database in an elastic pool. The elastic pool choice for each geo-secondary
database is separate and does not depend on the configuration of any other
replica. Each elastic pool is contained within a single logical server. Database
names must be unique in a pool so multiple geo secondaries cannot share the
same pool.
A geo-secondary that has finished
initial seeding can be failed over on demand by the user. If the primary is
unavailable, only the unplanned geo-failover can be used. The geo-secondary
becomes the new primary. Once the outage is mitigated, the system makes the
recovered primary a geo-secondary. Linking of all secondaries to the new
primary is automatically done and replication relationships are reconfigured.
After the outage that caused the geo-failover is mitigated, it may be desirable
to return the primary to its original region.
Preparing for a geo-failover
involves validating that the authentication and network access for the
secondary server are properly configured. The backup retention policy on the
secondary database matches that of the primary. This setting is not part of the
database, and it is not replicated from the primary. The default configuration
of a geo-secondary has a default PITR retention period of 7 days.